For many healthcare organisations, a NEN 7510 audit feels like an ISO 27001 audit with a healthcare flavour. That is half true. The management system requirements are almost identical to ISO/IEC 27001:2022, but in a healthcare organisation the auditor looks differently at access to patient data, logging, data exchange and suppliers. This article gives you a practical checklist to prepare for an internal audit or a certification audit against NEN 7510:2024, with the question the auditor asks for each topic and the evidence they want to see.
What exactly is NEN 7510:2024?
NEN 7510 is the Dutch standard for information security in healthcare. The 2024 edition has two parts:
- NEN 7510-1:2024: the management system requirements, based on ISO/IEC 27001:2022 (clauses 4 to 10).
- NEN 7510-2:2024: the controls, based on ISO/IEC 27002:2022, with healthcare-specific additions.
For Dutch healthcare providers the standard is not optional. The Decree on electronic data processing by healthcare providers (Besluit elektronische gegevensverwerking door zorgaanbieders) refers to NEN 7510, NEN 7512 (trust basis for data exchange) and NEN 7513 (logging of actions on electronic health records). Certification is done by an accredited certification body under the NCS 7510 certification scheme.
Use the checklist below as a working list, not as a replacement for the standard. The exact requirements are in your own copy of NEN 7510-1 and -2.
Does your organisation qualify?
Not every organisation can be certified against NEN 7510. Under the NCS 7510:2025 certification scheme it is meant for healthcare organisations (cluster Z) and for organisations that structurally manage health information of Dutch healthcare customers, such as IT suppliers to care providers (cluster B). The certification body checks at every audit whether the organisation has a lawful basis for processing health data. If that basis is missing at stage 2, the NEN 7510 audit must not go ahead, but the audit can be carried out as an ISO 27001 audit and extended to NEN 7510 later.
Checklist part 1: the management system (clauses 4 to 10)
| Topic | The auditor's question | Evidence to prepare |
|---|---|---|
| Context and interested parties (4.1, 4.2) | Which internal and external issues, and which requirements of patients, health insurers, regulators and care-chain partners, are relevant? | Context analysis and an overview of interested parties and their requirements, including laws and regulations. |
| Scope (4.3) | Which locations, processes and systems are in scope, and does it make sense that something is out of scope? | An approved scope statement with justification of exclusions and interfaces. |
| Leadership (5.1 to 5.3) | How does top management show ownership of information security? | Approved policy, assigned roles (for example CISO or security officer, DPO) and minutes that show direction. |
| Risk assessment (6.1.2, 8.2) | Have the risks to patient data and continuity of care really been assessed, with an owner, likelihood and impact? | Risk assessment with criteria, a current date and risk owners. |
| Risk treatment and SoA (6.1.3, 8.3) | Why is a control applicable or not, and is the implementation status up to date? | Statement of Applicability with a justification per control and a treatment plan with actions and deadlines. |
| Objectives and changes (6.2, 6.3) | Are there measurable objectives, and are changes to the ISMS planned? | Objectives with an owner and a measurement method; examples of planned changes. |
| Support (7.1 to 7.5) | Are staff competent and aware, and is documented information controlled? | Training overview, awareness activities, communication plan and document control with versions. |
| Monitoring and measurement (9.1) | What do you measure, who analyses it and what happens with the results? | Reports or dashboards with analysis and follow-up. |
| Internal audit (9.2) | Does the audit programme cover all requirements and relevant controls within the cycle, and are the auditors independent? | Audit programme, reports and findings with follow-up. |
| Management review (9.3) | Are all required inputs covered, and do decisions follow? | Management review minutes with inputs, decisions and actions. |
| Improvement and nonconformities (10.1, 10.2) | Are nonconformities analysed for root cause, and is the effectiveness of corrective actions checked? | Nonconformity register with root cause analysis, corrective actions and effectiveness review. |
Checklist part 2: controls with a healthcare focus
NEN 7510-2:2024 follows the structure of ISO/IEC 27002:2022: 93 controls in four themes (organisational, people, physical and technological). In healthcare, auditors usually look extra closely at the following points.
Access to patient data
- Is access to the electronic health record (EHR) and other care systems based on role and care relationship (5.15 to 5.18)?
- Are access rights adjusted promptly for joiners, movers and leavers, including temporary staff, interns and external care providers?
- Is strong authentication in place for remote access and for administrators (8.2, 8.5)?
- Evidence: authorisation matrix, a recent periodic access review, examples of processed access changes.
Logging and log review under NEN 7513
- Is it recorded who viewed or changed which patient record, and when (8.15, NEN 7513)?
- Are the logs actually reviewed, for example by sampling for unauthorised access, and is it defined who does this and how often (8.16)?
- Evidence: logging configuration, log review reports and follow-up of suspicious access.
Data exchange and suppliers
- Are there agreements on secure exchange with care-chain partners such as labs, pharmacies and other care providers (5.14, NEN 7512)?
- Is there a risk assessment and a data processing agreement for every supplier that processes patient data (5.19 to 5.22)?
- Are requirements for cloud services defined, and is supplier compliance monitored (5.23)?
- Evidence: supplier register, data processing agreements, supplier certificates or assurance reports, and minutes of supplier reviews.
Incidents, data breaches and continuity
- Is there a working procedure for security incidents, including the decision whether a personal data breach must be reported to the Dutch Data Protection Authority within 72 hours (5.24 to 5.28, GDPR Article 33)?
- Is it defined how care continues when the EHR or the network fails, and has this been tested (5.29, 5.30)?
- Are backups in place, and has a restore been tested recently (8.13)?
- Evidence: incident register, evaluations, continuity plan with test report, backup restore test.
People, workplace and technology
- Do staff get awareness activities that fit their work, for example on phishing and looking up patient records (6.3)?
- Are remote working, mobile devices and clear desk and clear screen arranged, also on wards and in consultation rooms (6.7, 7.7, 8.1)?
- Are vulnerabilities patched on time, and is the network segmented, including around networked medical devices (8.8, 8.20, 8.22)?
- Evidence: training overview, mobile device policy, patch reports and a network diagram.
Patterns that often lead to findings
- The Statement of Applicability was written once and no longer matches the risk assessment.
- NEN 7513 logging is switched on, but nobody can show that the logs are reviewed.
- Data processing agreements are missing for smaller suppliers or for new applications that departments bought themselves.
- The risk assessment is generic and misses healthcare-specific risks, such as unauthorised access to records or EHR downtime during a shift.
- The internal audit programme does not cover all requirements and relevant controls within the cycle.
- The management review misses required inputs or does not lead to decisions.
How much audit time does a NEN 7510 audit get?
The basis is the same as for ISO 27001: the table and the Annex D factors of ISO/IEC 27006-1:2024. The NCS 7510 scheme adds an uplift depending on the cluster: 4% for managers of personal health information (cluster B) and 8% for healthcare organisations (cluster Z), with a minimum of half a day. How the ISO 27006 calculation works and how IAF MD 1, MD 5 and MD 11 relate to it is explained in IAF MD 1 audit time calculation: how MD 1, MD 5, MD 11 and ISO/IEC 27006-1 fit together.
From checklist to report
A checklist on paper or in a spreadsheet works, but after the audit the retyping starts. In auditreporter.io, NEN 7510:2024 is in the standards library. You link the requirements to your audit agenda, tick off per agenda item what you covered, and record findings, evidence and notes straight away. Record everything during the audit and your report is ready when the audit ends, with no evening work afterwards. For certification bodies, the audit time calculator includes the NEN 7510 uplift. See all features.
Use this checklist in your next audit: create a free Basic account and set up your first NEN 7510 audit.
Sources
- NEN 7510-1:2024 and NEN 7510-2:2024, Information security in healthcare
- ISO/IEC 27001:2022 and ISO/IEC 27002:2022
- ISO/IEC 27006-1:2024
- NCS 7510:2025, certification scheme for NEN 7510 (clusters 3.1 and 3.2, stage 2 9.3.2.2, uplift per cluster C.3.8)
- Besluit elektronische gegevensverwerking door zorgaanbieders (Stb. 2017, 446)
- GDPR (Regulation (EU) 2016/679), Article 33